| Title | Addressing Water Consumption of Evaporative Coolers with Greywater |
| Publication Type | Conference Paper |
| LBNL Report Number | LBNL-5532E |
| Year of Publication | 2012 |
| Authors | Sahai, Rashmi, Nihar Shah, and Amol Phadke |
| Date Published | 07/2012 |
| Keywords | Air Conditioners, energy efficiency, Evaporative Cooling, Greywater |
| Abstract | Evaporative coolers (ECs) provide significant gains in energy efficiency compared to vapor compression air conditioners, but simultaneously have significant onsite water demand. This can be a major barrier to deployment in areas of the world with hot and arid climates. To address this concern, this study estimated where in the world evaporative cooling is suitable, the water consumption of ECs in these cities, and the potential that greywater can be used to reduce the consumption of potable water in ECs. ECs covered 69% of the cities where room air conditioners (ACs) are likely to be deployed, based on comfort conditions. Varying with climate, water consumption due to ECs ranged from 200 to 650 L/household/day, with the potential for greywater to provide 100% to 40% of this amount, respectively, based on conservative cooling load calculations. In the Mediterranean, the Middle East, Northern India, and the Midwestern |
| URL | https://isswprod.lbl.gov/library/view-docs/public/output/rpt81997.PDF |